Back to the septic review queue
Septic maintenance (pump-out): 7096 Pine Knoll Rd
ApprovedFiled Dec 14, 2025 by Quinn Calloway, Summit Wastewater. Filed from a phone.
Report
- Date of service
- Dec 14, 2025
- Tank size
- 750 gal
- Compartments
- 1
- Parts this system has
- Septic tank, Distribution box, Drainfield or mound
- Gallons pumped
- 753 gal
- Sludge depth
- 16 in
- Scum depth
- 6 in
- Baffles in good condition
- Yes
- Effluent filter
- Replaced
- Lids and risers secure
- Yes
- Distribution box level, clear and undamaged
- Yes
- Drainfield or mound: no surfacing, soggy ground or odor
- Yes
- Disposal site
- Permitted land-application site
- Repair needed
- No
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Quinn Calloway, current on the service date
- All required fields present
- Address matches parcel 029-49-01272
- Readings in range, no flags
- Result: passing. Next due date resets when approved.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
7096 Pine Knoll Rd
Owner: Quinn Okafor
Parcel 029-49-01272