Back to the septic review queue

Septic maintenance (pump-out): 3036 Laurel Dr

Approved

Filed Sep 21, 2025 by Alex Hollins, Keystone Pumping Co. Filed from a phone.

Report

Date of service
Sep 21, 2025
Tank size
750 gal
Compartments
2
Parts this system has
Septic tank, Distribution box, Drainfield or mound
Gallons pumped
646 gal
Sludge depth
29 in
Scum depth
7 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
Yes
Distribution box level, clear and undamaged
No
Drainfield or mound: no surfacing, soggy ground or odor
Yes
Disposal site
Regional wastewater plant
Repair needed
No
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Alex Hollins, current on the service date
  • All required fields present
  • Address matches parcel 029-52-01042
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Distribution box reported uneven, blocked or damaged.
  • No photos attached.
  • Result: passing. Next due date resets when approved.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

3036 Laurel Dr
Owner: Riley Okafor
Parcel 029-52-01042