Back to the septic review queue
Septic maintenance (pump-out): 5766 Sycamore Trl
ApprovedFiled Nov 3, 2024 by Jamie Ramirez, Keystone Septic Service. Filed from a phone.
Report
- Date of service
- Nov 3, 2024
- Tank size
- 1250 gal
- Compartments
- 1
- Parts this system has
- Septic tank, Drainfield or mound
- Gallons pumped
- 1151 gal
- Sludge depth
- 25 in
- Scum depth
- 6 in
- Baffles in good condition
- Yes
- Effluent filter
- Replaced
- Lids and risers secure
- Yes
- Drainfield or mound: no surfacing, soggy ground or odor
- Yes
- Disposal site
- Regional wastewater plant
- Repair needed
- Yes
- Repair needed: describe
- Cracked lid
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Jamie Ramirez, current on the service date
- All required fields present
- Address matches parcel 041-84-01069
- Sludge is over a third of a typical tank depth; check for system failure.
- No photos attached.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
5766 Sycamore Trl
Owner: Casey Whitcomb
Parcel 041-84-01069