Back to the septic review queue
Septic maintenance (pump-out): 3503 Laurel Dr
ApprovedFiled Jan 20, 2024 by Quinn Stroud, Summit Wastewater. Filed from a phone.
Report
- Date of service
- Jan 20, 2024
- Tank size
- 1000 gal
- Compartments
- 2
- Parts this system has
- Septic tank, Pump tank and effluent pump, High-water alarm, Drainfield or mound
- Gallons pumped
- 865 gal
- Sludge depth
- 29 in
- Scum depth
- 8 in
- Baffles in good condition
- Yes
- Effluent filter
- Cleaned
- Lids and risers secure
- Yes
- Pump runs and the floats turn it on and off
- No
- Alarm tested and working
- No
- Drainfield or mound: no surfacing, soggy ground or odor
- No
- Disposal site
- Regional wastewater plant
- Repair needed
- Yes
- Repair needed: describe
- Outlet baffle missing
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Quinn Stroud, current on the service date
- All required fields present
- Address matches parcel 061-44-01138
- Sludge is over a third of a typical tank depth; check for system failure.
- Pump or floats reported not working.
- Alarm reported not working.
- Surfacing, soggy ground or odor at the drainfield or mound.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
3503 Laurel Dr
Owner: Shawn Hollins
Parcel 061-44-01138