Back to the septic review queue

Septic maintenance (pump-out): 994 Ridgeview Way

Approved

Filed Sep 18, 2023 by Quinn Danner, Valley Wastewater. Filed from a phone.

Report

Date of service
Sep 18, 2023
Tank size
1000 gal
Compartments
2
Parts this system has
Septic tank, Distribution box, Drainfield or mound
Gallons pumped
1028 gal
Sludge depth
31 in
Scum depth
5 in
Baffles in good condition
No
Effluent filter
Cleaned
Lids and risers secure
No
Distribution box level, clear and undamaged
No
Drainfield or mound: no surfacing, soggy ground or odor
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Quinn Danner, current on the service date
  • All required fields present
  • Address matches parcel 069-52-01297
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Unsecured lids are a safety hazard.
  • Distribution box reported uneven, blocked or damaged.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

994 Ridgeview Way
Owner: Drew Benton
Parcel 069-52-01297